Circular fire dampers. SCFC-GD

Circular fire dampers, KOOLAIR, model SCFC-GD, S/UNE-EN 1366-2:2000. Circular fire damper class:

For sizes from Ø 200 to Ø 630 mm EI-180 (ho i ↔ o) S (500 Pa) or ceiling/floor slab.
For sizes from Ø 200 to Ø 800 mm EI-180 (ve i ↔ o) S (500 Pa) for wall.

Motor-driven fire damper monitoring systems

KOOLCOM is an electronic control system for fire dampers that allows the condition and functionality of each fire damper to be periodically and automatically monitored and checked. It can also close the dampers should the fire alarm be activated. While this system is capable of being managed by a BMS (Building Management System) system, KOOLCOM…

Stamped square diffusers. 52-FR-4 Stamp

Square diffuser model 52-FR-4 Stamp, KOOLAIR, air discharge in four directions. The free opening must be 150 mm more than the nominal dimension, except for the diffuser with a nominal dimension of 500 which must have a free opening of 130 mm. In addition, a diffuser with a nominal dimension of 300 will require an opening…

Multi-nozzles diffusers. DTP-GT

The DTP-GT, KOOLAIR, multi-nozzles diffuser is designed to solve any diffusion problem, either conventional or specific, capable of being adapted to the multiple and different problems generated by a right air diffusion installation. We are facing a versatile product with a different aesthetic and interior design needs, with low noise and excellent performance in the…

Square perforated plate diffuser. 56-FR

KOOLAIR square diffuser, model 56-FR-Q-PR, nominal dimensions _x_ mm incorporated in 595×595 mm micro-perforated tile. Incorporates a set of internal directional vanes that can be manually configured to supply air in 1,2,3 or 4 directions either during commissioning or by the end user.

Option to include plenum for lateral connection and regulating damper.

Long-throw nozzles – DF-49-ROT

The new DF-49-ROT, KOOLAIR, combines long-throw efficiency with a more harmonious design, the novelty in this model relative to the nozzle DF49 is the inclusion of a rotational element that reduces air jet for applications where you need shorter throw. The stylised lines of the nozzles and the possibility of matching current decorative styles make…

Ventilation hoods.

In all our KOOLAIR models, the design allows air currents to create a negative pressure inside the chimney head that conveys and exhausts rising gases and smoke toward the outside regardless of wind direction.

Measurement stations. EM

The Koolair model EM measurement stations are elements designed to measure the air volume which passes through it. The EMC casing is circular with diameters from 80 to 630 mm, corresponding to the normalised diameters for circular ducts. The EMQ casing is rectangular with dimensions LxH mm. In the inlet duct a cross-shaped probe is…