Circular fire dampers. SCFC-PD
Circular fire dampers, KOOLAIR, model SCFC-PD, S/UNE-EN 1366-2:2000 EI-120 (ve i↔o) and (ho i↔o). Fire resistence 2 hours. Rectangular fire damper class EI-120.
Dimensions from Ø 100 to Ø 355 mm.
Circular fire dampers, KOOLAIR, model SCFC-PD, S/UNE-EN 1366-2:2000 EI-120 (ve i↔o) and (ho i↔o). Fire resistence 2 hours. Rectangular fire damper class EI-120.
Dimensions from Ø 100 to Ø 355 mm.
Rectangular fire damper, KOOLAIR, model SCFR-PD, S/UNE-EN 1366-2:2000 EI-120 (ve i↔o) and (ho i↔o). Fire resistence 2 hours. Rectangular fire damper class EI-120.
Dimensions from 200 x 100 to 800 x 600 mm.
The diffusers, KOOLAIR, type S-90-GV, are variable geometry units for installation at considerable heights. They are used in industrial environments, in both heating and cooling systems. They consist of a perforated cylinder, inner discs, and a damper to change the discharge air flow. The air flows into the cylinder guide through the orifice plate, when…
The diffuser, KOOLAIR, type LADES-I, was designed to be installed in rooms with high ceilings (not higher than 5 or 6 m) such as industrial facilities, large stores, etc. The diffuser is octagonal, and the upper section of the terminal is fitted with multiple nozzles for hot air supply. The lower section has a perforated…
The diffusers, KOOLAIR, type S-90, are displacement units for floor installation. The unit includes upper and lower covers and a perforated air distribution face plate. Connections can be made through the upper or lower cover. The units are of galvanised steel sheet construction with aluminium sections and include an air equalising plate (painted in black)…
The diffusers, KOOLAIR, type S-90, are displacement units for floor installation. The unit includes upper and lower covers and a perforated air distribution face plate. Connections can be made through the upper or lower cover. The units are of galvanised steel sheet construction with aluminium sections and include an air equalising plate (painted in black)…
Chilled ceiling elements, KOOLAIR, type TFK, can be installed in an exposed system or combined with grid ceilings. TFK Chilled Ceilings, without supply air, are used for cooling in a room. As in all surface cooling systems, TFK has the energy benefits of using water as a vehicle to carry the cooling power to the…
Horizontal Inductor unit to supply air in one direction, KOOLAIR, model IHK, length (900/1200/1500) mm, width 700 mm and height 200 mm, for installation in false ceilings. Incorporates air discharge grille available in different designs, for horizontal air diffusion Coanda effect air mixture (primary and secondary). Induction grille available in different designs, hinged or removable…
Passive chilled beams, KOOLAIR, model VPK, without supply air, are used for cooling in a room. As in all water conditioning systems, choosing passive chilled beam has the energy benefits of using water as a vehicle to carry the cooling power to the rooms. The type VPK passive chilled beam comprises a casing and a…
Active chilled beam, KOOLAIR, model VFK 300, length from 600 to 3000, width 300 mm and height 200 mm, integrated in the false ceiling or plasterboard. It incorporates 2 linear lateral side slot diffusers. For horizontal supply with Coanda effect of the mixed air flow (primary and secondary air). Hinged perforate plate face, available in…